CIMR-VU4A0002FAA Yaskawa Electric AC VFD Variable Frequency Drive Repair
CIMR-VU4A0002FAA Yaskawa Electric AC VFD Variable Frequency Drive Repair
SKU: 36821

CIMR-VU4A0002FAA Yaskawa Electric AC VFD Variable Frequency Drive Repair

Industrial VFD Repair Service – Save Big and Keep Your Settings. Our services are fast and easy. Send us your failed VFD Variable Frequency Drive. We will quickly repair your faulty VFD. We provide a quick turnaround time and a high repair success rate at a low repair cost.
UpFix is NOT an authorized distributor for Yaskawa Electric.

Experience the most cost-effective and efficient solution for your industrial VFD issues with UpFix expert repair service. By choosing to repair your original VFD, you not only save significantly compared to the cost of buying a new unit, but you also retain all the custom programming and configurations specific to your operational needs.
  • Estimated Repair Time is 3-5 business days.
  • 2 Year Warranty
  • Free Round-Trip Shipping
  • Real-Time Repair Tracking
  • Our service is 100% guaranteed or your money back. Order today and save!

International Shipping Available:
Ships to USA and Canada

Free round trip shipping available at online checkout!
$161.28
Repair yours
Send your original part for repair service
$161.28
Service Price:
Options Price:
Total:
In-stock item
Send me a good working part
Description

This is a repair service for CIMR-VU4A0002FAA Yaskawa Electric AC VFD Variable Frequency Drive Repair.
UpFix is NOT an authorized distributor for Yaskawa Electric.

Once we receive your part, our highly trained and IPC certified technicians will run tests to identify the source of the problem. We will rebuild your part, replacing not only the failed components, but all components that are usually known to fail or go bad in this part. We want to make your experience as effortless as possible. All you have to do is send your part to us. Then after receiving the part back from us, just reinstall it and you’re back in business!

Estimated Repair Time is 3-5 business days.

International Shipping Available: Ships to USA and Canada

How it works


We take pride in our work and will take it a step further and fully inspect your control board and will replace failure prone components or parts that may be failing in the future. Each part is fully tested to make sure it passes a full functional test.

Our service is 100 percent guaranteed or your money back. We stand by our services, thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

Our goal is to save you hundreds of dollars, while continuing to provide an eco-friendly solution that reduces pollution. We drive our business towards consistent and profitable growth, with integrity and a commitment to the people and communities where we live and work. Our service is 100% guaranteed or your money back.




This repair service will fix these issues:

  • Auto Tune Failure
  • Checksum Fault
  • Does Not Enable
  • Does Not Power
  • Fails Under Load
  • Fans Not Turning On
  • Ground Fault
  • Heatsink Fault
  • I/O Terminal Not Working
  • Input Phase Fault
  • Keypad Issue
  • Keys Dont Press
  • No Output
  • Output Phase Fault
  • Output Runs Erratically
  • Overcurrent Fault
  • Overvoltage Fault
  • Power Loss
  • Undervoltage Fault
  • Unit Had Blown Up
  • Unit Smoked



Cost-Effective
Repairing your existing VFD can be substantially more affordable than purchasing a new one. Enjoy significant savings while maintaining optimal functionality.

No Reconfiguration Needed
One of the biggest advantages of repairing your original VFD is the elimination of reprogramming. Your VFD will be returned to you with all its original settings intact, ensuring a seamless reintroduction into your system without the need for costly and time-consuming reconfiguration.

Quick Turnaround
We understand the importance of minimizing downtime. Our skilled technicians ensure a quick and efficient repair process, getting your operations back up and running in no time.

Quality Assurance
We use only the highest quality parts and the latest techniques in our repair processes, ensuring your VFD returns to you in top-notch condition, often better than its pre-fault state.

Extended Life for Your Equipment
Repairing and maintaining your existing VFD can significantly extend its life, making it a sustainable choice for your business and the environment.

Expert Support
Our team of experienced technicians is well-versed in a wide range of VFD brands and models, providing you with knowledgeable support and advice every step of the way.

Our Commitment
At UpFix, we are committed to providing you with a reliable, high-quality repair service that keeps your operations smooth and efficient. Trust us to restore your VFD to its optimal performance, ensuring your business runs uninterrupted.
Will this service fix my problems?

A full diagnostic check should first be performed to eliminate all other possible causes for your symptoms, even if the symptoms match those specified on the common fault description.

If you send a unit in good working condition due to misdiagnosis, and our testing determines that there are no issues or faults with the unit, or if the part is beyond repair, then you will only be responsible for the shipping costs and a bench test fee of $39.99 may be applied.

IMPORTANT! If you are not sure that this part is the cause of the fault then we recommend that you do not go ahead with this purchase and instead seek further professional advice and diagnosis.


Benefits of using us:
  • Free round trip shipping
  • Fast & easy process
  • High quality components
  • 100% guaranteed or your money back
  • Save hundreds of dollars
  • Amazing customer service and support
  • No programming needed
  • Plug-n-play
  • Refurbished and tested to meet manufacturers specifications
  • IPC certified technicians (highest standard of quality craftsmanship)
  • Hassle-free warranty that is much better than the warranties you get for new replacements.
Warranty

Warranty

Our service is 100 percent guaranteed or your money back.

For a full 24 months, our no-hassle warranty covers the repair. We will fix the item again if the repair fails within 24 months. If the component is not repairable, we will, at our discretion, either replace the part entirely or refund the cost of the repair.

We stand by our services – If the part is going to fail, itll fail within the first 3 months. Thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

How It Works

How it works

Our services are fast and easy. Reducing downtime is extremely important to us. Our standard repair is usually under 1 week. Meanwhile, offering a high-quality repair service with a focus on quick, long-lasting repairs at competitive prices.


We take pride in our work and not only fully inspecting/repairing your faulty part, but will take it a step further and will replace failure prone components or parts that may be failing in the future. Each control board is fully tested to make sure it passes a full functional test. Our service is 100 percent guaranteed or your money back.


  1. Carefully remove your part.
  2. Securely pack your part, using the correct box so that your part cannot be damaged in transit. Take special care when packing.
  3. Add item to shopping cart and check out. We will provide you with shipping label to send the part to us. You will not need to pay anything until your part is full repaired.
  4. Inside the package include: Your Name, Return Address, Phone Number.


  5. International Shipping Available
    We ship to USA and Canada
Part Numbers

CIMRVU4A0002FAA

Error Codes
CodeDescriptionRecommended Action
0001HUndervoltage (Uv)
0002HUndervoltage (Uv1)
0002HOvervoltage (ov)
0003HHeatsink Overheat (oH)
0003HControl Power Supply Undervoltage (Uv2)
0004HSoft Charge Circuit Fault (Uv3)
0004HDrive Overheat (oH2)
0005HOvertorque 1 (oL3)
0005HIGBT Short Circuit (SC)
0006HGround Fault (GF)
0006HOvertorque 2 (oL4)
0007HRun commands input error (EF)
0007HOvercurrent (oC)
0008HOvervoltage (ov)
0008HDrive Baseblock (bb)
0009HExternal Fault 3, input terminal S3 (EF3)
0009HHeatsink Overheat (oH)
000AHHeatsink Overheat (oH1)
000AHExternal Fault 4, input terminal S4 (EF4)
000BHExternal Fault 5, input terminal S5 (EF5)
000BHMotor Overload (oL1)
000CHDrive Overload (oL2)
000CHExternal Fault 6, input terminal S6 (EF6)
000DHExternal Fault 7, input terminal S7 (EF7)
000DHOvertorque Detection 1 (oL3)
000EHOvertorque Detection 2 (oL4)
000FHReserved
000FHDynamic Braking Transistor (rr)
0010HBraking Resistor Overheat (rH)
0010HOverspeed (oS)
0011HExternal Fault at input terminal S3 (EF3)
0011HExcessive Speed Deviation (dEv)
0012HExternal Fault at input terminal S4 (EF4)
0012HPG Disconnected (PGo)
0013HExternal Fault at input terminal S5 (EF5)
0013HDigital operator connection fault (oPr)
0014HExternal Fault at input terminal S6 (EF6)
0014HMEMOBUS/Modbus Communication Error (CE)
0015HExternal Fault at input terminal S7 (EF7)
0015HOption Communication Error (bUS)
0016HSerial Communication Transmission Error (CALL)
0017HMotor Overload (oL1)
0018HOverspeed (oS)
0018HDrive Overload (oL2)
0019HExcessive Speed Deviation (dEv)
001AHOption Card External Fault (EF0)
001AHPG Disconnect (PGo)
001BHInput Phase Loss (PF)
001BHMotor Switch command input during run (rUn)
001CHOutput Phase Loss (LF)
001DHMotor Overheat (PTC input) (oH3)
001DHSerial Communication Transmission Error (CALL)
001EHDigital Operator Connection (oPr)
001EHUndertorque Detection 1 (UL3)
001FHEEPROM Write Error (Err)
001FHUndertorque Detection 2 (UL4)
0020HMotor Overheat (PTC input) (oH4)
0020HMEMOBUS/Modbus Test Mode Fault (SE)
0021HMEMOBUS/Modbus Communication Error (CE)
0022HMotor Overheat (oH3)
0022HOption Communication Error (bUS)
0025HControl fault (CF)
0027HPROFIBUS-DP Option External Fault (EF0)
0027HPID Feedback Loss (FbL)
0028HPID Feedback Loss (FbL)
0028HPID Feedback Loss (FbH)
0029HUndertorque Detection 1 (UL3)
002AHUndertorque Detection 2 (UL4)
002AHDrive Disabled (dnE)
002BHPG Disconnected (PGo)
002BHHigh Slip Braking Overload (oL7)
0030HHardware Fault (including oFx)
0031HMECHATROLINK Watchdog Timer Error (E5)
0032HStation Address Setting Error (AEr)
0033HMECHATROLINK Comm. Cycle Setting Error (CyC)
0034HHigh Current Alarm (HCA)
0036HOutput Current Imbalance (LF2)
0037HPullout Detection (Sto)
0038HPG Disconnected (PGo)
0039HExternal Fault (input terminal S1) (EF1)
0039HMECHATROLINK Watchdog Timer Error (E5)
003AHExternal Fault (input terminal S2) (EF2)
003BHToo many speed search restarts (SEr)
003BHSafe Disable Input (HbbF)
003CHSafe Disable Input (Hbb)
003DHMechanical Weakening Detection 1 (oL5)
003EHMechanical Weakening Detection 2 (UL5)
0041HPID Feedback Loss (FbH)
0042HExternal Fault 1, input terminal S1 (EF1)
0043HExternal Fault 2, input terminal S2 (EF2)
0044HMechanical Weakening Detection 1 (oL5)
0045HMechanical Weakening Detection 2 (UL5)
0046HCurrent Offset Fault (CoF)
0049HDriveWorksEZ Alarm (dWAL)
0049HDriveWorksEZ Fault (dWFL)
0083HA/D Conversion Error (CPF02)
0084HPWM Data Fault (CPF03)
0087HDrive specification mismatch during Terminal Board or Control Board replacement (CPF06)
0088HTerminal Board Communication Fault (CPF07)
0089HEEPROM Serial Communication Fault (CPF08)
008CHRAM fault (CPF11)
008DHFlash memory circuit exception (CPF12)
008EHWatchdog circuit exception (CPF13)
008FHControl Circuit Fault (CPF14)
0091HClock Fault (CPF16)
0092HTiming Fault (CPF17)
0093HControl Circuit Fault (CPF18)
0094HControl Circuit Fault (CPF19)
0095HHardware fault at power up (CPF20)
0096HHardware fault at communication start up (CPF21)
0097HA/D Conversion Fault (CPF22)
0098HPWM Feedback Fault (CPF23)
0099HDrive capacity signal fault (CPF24)
0101HOption compatibility error (oFA00)
0102HOption not properly connected (oFA01)
0104HOption Self-diagnostics Error (oFA03)
0105HOption Flash Write Mode Error (oFA04)
01HFunction Code ErrorCAUSE: • Attempted to set a function code from a PLC other than 03H, 08H, and 10H.
02HRegister Number ErrorCAUSE: • A register number specified in the command message does not exist. • Attempted to send a broadcast message using other register numbers than 0001H or 0002H.
03HBit Count ErrorCAUSE: • Read data or write data is greater than 16 bits. Invalid command message quantity. • In a write message, the “Number of Data Items” contained within the message does not equal twice the amount of data words (i.e., the total of Data 1+ Data 2, etc.).
21HData Setting ErrorCAUSE: • Control data or parameter write data is outside the allowable setting range. • Attempted to write a contradictory parameter setting.
22HWrite Mode ErrorCAUSE: • Attempted to write while the drive was operating to a parameter that cannot be written to during run. • During an EEPROM data error (CPF06), the master attempted to write to a parameter other than A1-00 to -05, E1-03, or o2-04. • Attempted to write to read-only data
23HDC Bus Undervoltage Write ErrorCAUSE: • Attempted to write from the master during an undervoltage fault (Uv1). • Attempted to execute and Enter command during Uv1.
24HWrite Error During Parameter ProcessCAUSE: • Master attempted writing to the drive while the drive was processing parameter data.
Models

This control board may be found in models similar to the following:

CIMR-VU4A0002FAA

 
Related products
CFW701 B 24P0 T2 DB55C3 Weg AC VFD Variable Frequency Drive Repair
CFW701 B 24P0 T2 DB55C3 Weg AC VFD Variable Frequency Drive Repair
$360.06
View Details
ACS550-U1-125A-4 ABB Asea Brown Boveri AC VFD Variable Frequency Drive Repair
ACS550-U1-125A-4 ABB Asea Brown Boveri AC VFD Variable Frequency Drive Repair
$3,087.54
View Details
CFW09-0032-T-5060-E-O-B5-Z Weg AC VFD Variable Frequency Drive Repair
CFW09-0032-T-5060-E-O-B5-Z Weg AC VFD Variable Frequency Drive Repair
$1,224.30
View Details
ACS550-PD-077A-6 ABB Asea Brown Boveri AC VFD Variable Frequency Drive Repair
ACS550-PD-077A-6 ABB Asea Brown Boveri AC VFD Variable Frequency Drive Repair
$4,322.56
View Details
×
CIMR-VU4A0002FAA Yaskawa Electric AC VFD Variable Frequency Drive Repair
1 image
  • CIMR-VU4A0002FAA Yaskawa Electric AC VFD Variable Frequency Drive Repair image
×
Contact Us