25A-D010N104 Allen Bradley AC VFD Variable Frequency Drive Repair
25A-D010N104 Allen Bradley AC VFD Variable Frequency Drive Repair
SKU: 30237

25A-D010N104 Allen Bradley AC VFD Variable Frequency Drive Repair

Industrial VFD Repair Service – Save Big and Keep Your Settings. Our services are fast and easy. Send us your failed VFD Variable Frequency Drive. We will quickly repair your faulty VFD. We provide a quick turnaround time and a high repair success rate at a low repair cost.
UpFix is NOT an authorized distributor for Allen Bradley.

Experience the most cost-effective and efficient solution for your industrial VFD issues with UpFix expert repair service. By choosing to repair your original VFD, you not only save significantly compared to the cost of buying a new unit, but you also retain all the custom programming and configurations specific to your operational needs.
  • Estimated Repair Time is 3-5 business days.
  • 2 Year Warranty
  • Free Round-Trip Shipping
  • Real-Time Repair Tracking
  • Our service is 100% guaranteed or your money back. Order today and save!

International Shipping Available:
Ships to USA and Canada

Free round trip shipping available at online checkout!
$287.64
Repair yours
Send your original part for repair service
$287.64
Service Price:
Options Price:
Total:
In-stock item
Send me a good working part
Description

This is a repair service for 25A-D010N104 Allen Bradley AC VFD Variable Frequency Drive Repair.
UpFix is NOT an authorized distributor for Allen Bradley.

Once we receive your part, our highly trained and IPC certified technicians will run tests to identify the source of the problem. We will rebuild your part, replacing not only the failed components, but all components that are usually known to fail or go bad in this part. We want to make your experience as effortless as possible. All you have to do is send your part to us. Then after receiving the part back from us, just reinstall it and you’re back in business!

Estimated Repair Time is 3-5 business days.

International Shipping Available: Ships to USA and Canada

How it works


We do not replace housing or cases

We take pride in our work and will take it a step further and fully inspect your control board and will replace failure prone components or parts that may be failing in the future. Each part is fully tested to make sure it passes a full functional test.

Our service is 100 percent guaranteed or your money back. We stand by our services, thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

Our goal is to save you hundreds of dollars, while continuing to provide an eco-friendly solution that reduces pollution. We drive our business towards consistent and profitable growth, with integrity and a commitment to the people and communities where we live and work. Our service is 100% guaranteed or your money back.



Don't send your part for repair if
Need case or housing replaced


This repair service will fix these issues:

  • Auto Tune Failure
  • Checksum Fault
  • Does Not Enable
  • Does Not Power
  • Fails Under Load
  • Fans Not Turning On
  • Ground Fault
  • Heatsink Fault
  • I/O Terminal Not Working
  • Input Phase Fault
  • Keypad Issue
  • Keys Dont Press
  • No Output
  • Output Phase Fault
  • Output Runs Erratically
  • Overcurrent Fault
  • Overvoltage Fault
  • Power Loss
  • Undervoltage Fault
  • Unit Had Blown Up
  • Unit Smoked



Cost-Effective
Repairing your existing VFD can be substantially more affordable than purchasing a new one. Enjoy significant savings while maintaining optimal functionality.

No Reconfiguration Needed
One of the biggest advantages of repairing your original VFD is the elimination of reprogramming. Your VFD will be returned to you with all its original settings intact, ensuring a seamless reintroduction into your system without the need for costly and time-consuming reconfiguration.

Quick Turnaround
We understand the importance of minimizing downtime. Our skilled technicians ensure a quick and efficient repair process, getting your operations back up and running in no time.

Quality Assurance
We use only the highest quality parts and the latest techniques in our repair processes, ensuring your VFD returns to you in top-notch condition, often better than its pre-fault state.

Extended Life for Your Equipment
Repairing and maintaining your existing VFD can significantly extend its life, making it a sustainable choice for your business and the environment.

Expert Support
Our team of experienced technicians is well-versed in a wide range of VFD brands and models, providing you with knowledgeable support and advice every step of the way.

Our Commitment
At UpFix, we are committed to providing you with a reliable, high-quality repair service that keeps your operations smooth and efficient. Trust us to restore your VFD to its optimal performance, ensuring your business runs uninterrupted.
Will this service fix my problems?

A full diagnostic check should first be performed to eliminate all other possible causes for your symptoms, even if the symptoms match those specified on the common fault description.

If you send a unit in good working condition due to misdiagnosis, and our testing determines that there are no issues or faults with the unit, or if the part is beyond repair, then you will only be responsible for the shipping costs and a bench test fee of $39.99 may be applied.

IMPORTANT! If you are not sure that this part is the cause of the fault then we recommend that you do not go ahead with this purchase and instead seek further professional advice and diagnosis.


Benefits of using us:
  • Free round trip shipping
  • Fast & easy process
  • High quality components
  • 100% guaranteed or your money back
  • Save hundreds of dollars
  • Amazing customer service and support
  • No programming needed
  • Plug-n-play
  • Refurbished and tested to meet manufacturers specifications
  • IPC certified technicians (highest standard of quality craftsmanship)
  • Hassle-free warranty that is much better than the warranties you get for new replacements.
Warranty

Warranty

Our service is 100 percent guaranteed or your money back.

For a full 24 months, our no-hassle warranty covers the repair. We will fix the item again if the repair fails within 24 months. If the component is not repairable, we will, at our discretion, either replace the part entirely or refund the cost of the repair.

We stand by our services – If the part is going to fail, itll fail within the first 3 months. Thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

How It Works

How it works

Our services are fast and easy. Reducing downtime is extremely important to us. Our standard repair is usually under 1 week. Meanwhile, offering a high-quality repair service with a focus on quick, long-lasting repairs at competitive prices.


We take pride in our work and not only fully inspecting/repairing your faulty part, but will take it a step further and will replace failure prone components or parts that may be failing in the future. Each control board is fully tested to make sure it passes a full functional test. Our service is 100 percent guaranteed or your money back.


  1. Carefully remove your part.
  2. Securely pack your part, using the correct box so that your part cannot be damaged in transit. Take special care when packing.
  3. Add item to shopping cart and check out. We will provide you with shipping label to send the part to us. You will not need to pay anything until your part is full repaired.
  4. Inside the package include: Your Name, Return Address, Phone Number.


  5. International Shipping Available
    We ship to USA and Canada
Part Numbers

25AD010N104

Error Codes
CodeDescriptionRecommended Action
F000No Fault-
F002Auxiliary Input• Check remote wiring. • Verify communications programming for intentional fault.
F003Power Loss• Monitor the incoming AC line for low voltage or line power interruption. • Check input fuses. • Reduce load.
F004UnderVoltageMonitor the incoming AC line for low voltage or line power interruption.
F005OverVoltageMonitor the AC line for high line voltage or transient conditions. Bus overvoltage can also be caused by motor regeneration. Extend the decel time or install dynamic brake option.
F006Motor Stalled• Increase P041, A442, A444, A446 [Accel Time x] or reduce load so drive output current does not exceed the current set by parameter A484, A485 [Current Limit x] for too long. • Check for overhauling load.
F007Motor Overload• An excessive motor load exists. Reduce load so drive output current does not exceed the current set by parameter P033 [Motor OL Current]. • Verify A530 [Boost Select] setting.
F008Heatsink OvrTmp• Check for blocked or dirty heat sink fins. Verify that ambient temperature has not exceeded the rated ambient temperature. • Check fan.
F009CC OvrTmp• Check product ambient temperature. • Check for airflow obstruction. • Check for dirt or debris. • Check fan.
F012HW OverCurrentCheck programming. Check for excess load, improper A530 [Boost Select] setting, DC brake volts set too high or other causes of excess current.
F013Ground FaultCheck the motor and external wiring to the drive output terminals for a grounded condition.
F015Load Loss• Verify connections between motor and load. • Verify level and time requirements.
F021Output Ph Loss• Verify motor wiring. • Verify motor.
F029Analog In Loss• Check for broken/loose connections at inputs. • Check parameters.
F033Auto Rstrt TriesCorrect the cause of the fault and manually clear.
F038Phase U to Gnd• Check the wiring between the drive and motor. • Check motor for grounded phase. • Replace drive if fault cannot be cleared.
F039Phase V to Gnd• Check the wiring between the drive and motor. • Check motor for grounded phase. • Replace drive if fault cannot be cleared.
F040Phase W to Gnd• Check the wiring between the drive and motor. • Check motor for grounded phase. • Replace drive if fault cannot be cleared.
F041Phase UV Short• Check the motor and drive output terminal wiring for a shorted condition. • Replace drive if fault cannot be cleared.
F042Phase UW Short• Check the motor and drive output terminal wiring for a shorted condition. • Replace drive if fault cannot be cleared.
F043Phase VW Short• Check the motor and drive output terminal wiring for a shorted condition. • Replace drive if fault cannot be cleared.
F048Params Defaulted• Clear the fault or cycle power to the drive. • Program the drive parameters as needed.
F059Safety OpenCheck safety input signals. If not using safety, verify and tighten jumper for I/O terminals S1, S2 and S+.
F063SW OverCurrent• Verify connections between motor and load. • Verify level and time requirements.
F064Drive OverloadReduce load or extend Accel Time.
F070Power Unit• Check maximum ambient temperature has not been exceeded. • Cycle power. • Replace drive if fault cannot be cleared.
F071DSI Net Loss• Cycle power. • Check communications cabling. • Check Modbus or DSI setting. • Check Modbus or DSI status.
F072Opt Net Loss• Cycle power. • Check communications cabling. • Check network adapter setting. • Check external network status.
F073EN Net Loss• Cycle power. • Check communications cabling. • Check EtherNet/IP setting. • Check external network status.
F080Autotune FailureRestart procedure.
F081DSI Comm Loss• Cycle power. • Check communications cabling. • Check Modbus or DSI setting. • Check Modbus or DSI status. • Modify using C125 [Comm Loss Action]. • Connecting I/O terminals C1 and C2 to ground may improve noise immunity. • Replace wiring, Modbus master device, or control module.
F082Opt Comm Loss• Cycle power. • Reinstall option card in drive. • Modify using C125 [Comm Loss Action]. • Replace wiring, port expander, option card, or control module.
F083EN Comm Loss• Cycle power. • Check EtherNet/IP setting. • Check drive’s Ethernet settings and diagnostic parameters. • Modify using C125 [Comm Loss Action]. • Replace wiring, Ethernet switch, or control module.
F091Encoder Loss• Check Wiring. • If P047, P049, P051 [Speed Referencex] = 16 “Positioning” and A535 [Motor Fdbk Type] = 5 “Quad Check”, swap the Encoder channel inputs or swap any two motor leads. • Replace encoder.
F094Function LossClose input to the terminal and cycle power.
F100Parameter ChksumSet P053 [Reset To Defalts] to 2 “Factory Rset”
F101External StorageSet P053 [Reset To Defalts] to 2 “Factory Rset”
F105C Connect ErrClear fault and verify all parameter settings. Do not remove or install the control module while power is applied.
F106Incompat C-P• Change to a different power module. • Change to a PowerFlex 523 control module.
F107Replaced C-P• Change to a different power module. • Replace control module if changing power module does not work.
F109Mismatch C-PSet P053 [Reset To Defalts] to 3 “Power Reset”.
F110Keypad Membrane• Cycle power. • Replace control module if fault cannot be cleared.
F111Safety Hardware• Check safety input signals. If not using safety, verify and tighten jumper for I/O terminals S1, S2 and S+. • Replace control module if fault cannot be cleared.
F114uC Failure• Cycle power. • Replace control module if fault cannot be cleared.
F122I/O Board Fai• Cycle power. • Replace drive or control module if fault cannot be cleared.
F125Flash Update ReqPerform a firmware flash update operation to attempt to load a valid set of firmware.
F126NonRecoverablErr• Clear fault or cycle power to the drive. • Replace drive or control module if fault cannot be cleared.
F127DSIFlashUpdatReqPerform a firmware flash update operation using DSI communications to attempt to load a valid set of firmware.
Models

This control board may be found in models similar to the following:

25A-D010N104

 
Related products
600FR4041 ABB Asea Brown Boveri AC VFD Variable Frequency Drive Repair
600FR4041 ABB Asea Brown Boveri AC VFD Variable Frequency Drive Repair
$10,506.65
View Details
20BB042A3AYNBND0NNAD Allen Bradley AC VFD Variable Frequency Drive Repair
20BB042A3AYNBND0NNAD Allen Bradley AC VFD Variable Frequency Drive Repair
$2,087.53
View Details
ATV-08EU-18M2 Schneider Electric AC VFD Variable Frequency Drive Repair
ATV-08EU-18M2 Schneider Electric AC VFD Variable Frequency Drive Repair
$560.00
View Details
D5588 GE General Electric AC VFD Variable Frequency Drive Repair
D5588 GE General Electric AC VFD Variable Frequency Drive Repair
$206.80
View Details
×
25A-D010N104 Allen Bradley AC VFD Variable Frequency Drive Repair
1 image
  • 25A-D010N104 Allen Bradley AC VFD Variable Frequency Drive Repair image
×
Contact Us