SKU: 30952

22B-B033N204 Allen Bradley AC VFD Variable Frequency Drive Repair

Industrial VFD Repair Service – Save Big and Keep Your Settings. Our services are fast and easy. Send us your failed VFD Variable Frequency Drive. We will quickly repair your faulty VFD. We provide a quick turnaround time and a high repair success rate at a low repair cost.
UpFix is NOT an authorized distributor for Allen Bradley.

Experience the most cost-effective and efficient solution for your industrial VFD issues with UpFix expert repair service. By choosing to repair your original VFD, you not only save significantly compared to the cost of buying a new unit, but you also retain all the custom programming and configurations specific to your operational needs.
  • Estimated Repair Time is 3-5 business days.
  • 2 Year Warranty
  • Free Round-Trip Shipping
  • Real-Time Repair Tracking
  • Our service is 100% guaranteed or your money back. Order today and save!

International Shipping Available:
Ships to USA and Canada

Free round trip shipping available at online checkout!
$494.50
Repair yours
Send your original part for repair service
$494.50
Service Price:
Options Price:
Total:
In-stock item
Send me a good working part
Description

This is a repair service for 22B-B033N204 Allen Bradley AC VFD Variable Frequency Drive Repair.
UpFix is NOT an authorized distributor for Allen Bradley.

Once we receive your part, our highly trained and IPC certified technicians will run tests to identify the source of the problem. We will rebuild your part, replacing not only the failed components, but all components that are usually known to fail or go bad in this part. We want to make your experience as effortless as possible. All you have to do is send your part to us. Then after receiving the part back from us, just reinstall it and you’re back in business!

Estimated Repair Time is 3-5 business days.

International Shipping Available: Ships to USA and Canada

How it works


We take pride in our work and will take it a step further and fully inspect your control board and will replace failure prone components or parts that may be failing in the future. Each part is fully tested to make sure it passes a full functional test.

Our service is 100 percent guaranteed or your money back. We stand by our services, thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

Our goal is to save you hundreds of dollars, while continuing to provide an eco-friendly solution that reduces pollution. We drive our business towards consistent and profitable growth, with integrity and a commitment to the people and communities where we live and work. Our service is 100% guaranteed or your money back.




This repair service will fix these issues:

  • Auto Tune Failure
  • Checksum Fault
  • Does Not Enable
  • Does Not Power
  • Fails Under Load
  • Fans Not Turning On
  • Ground Fault
  • Heatsink Fault
  • I/O Terminal Not Working
  • Input Phase Fault
  • Keypad Issue
  • Keys Dont Press
  • No Output
  • Output Phase Fault
  • Output Runs Erratically
  • Overcurrent Fault
  • Overvoltage Fault
  • Power Loss
  • Undervoltage Fault
  • Unit Had Blown Up
  • Unit Smoked



Cost-Effective
Repairing your existing VFD can be substantially more affordable than purchasing a new one. Enjoy significant savings while maintaining optimal functionality.

No Reconfiguration Needed
One of the biggest advantages of repairing your original VFD is the elimination of reprogramming. Your VFD will be returned to you with all its original settings intact, ensuring a seamless reintroduction into your system without the need for costly and time-consuming reconfiguration.

Quick Turnaround
We understand the importance of minimizing downtime. Our skilled technicians ensure a quick and efficient repair process, getting your operations back up and running in no time.

Quality Assurance
We use only the highest quality parts and the latest techniques in our repair processes, ensuring your VFD returns to you in top-notch condition, often better than its pre-fault state.

Extended Life for Your Equipment
Repairing and maintaining your existing VFD can significantly extend its life, making it a sustainable choice for your business and the environment.

Expert Support
Our team of experienced technicians is well-versed in a wide range of VFD brands and models, providing you with knowledgeable support and advice every step of the way.

Our Commitment
At UpFix, we are committed to providing you with a reliable, high-quality repair service that keeps your operations smooth and efficient. Trust us to restore your VFD to its optimal performance, ensuring your business runs uninterrupted.
Will this service fix my problems?

A full diagnostic check should first be performed to eliminate all other possible causes for your symptoms, even if the symptoms match those specified on the common fault description.

If you send a unit in good working condition due to misdiagnosis, and our testing determines that there are no issues or faults with the unit, or if the part is beyond repair, then you will only be responsible for the shipping costs and a bench test fee of $39.99 may be applied.

IMPORTANT! If you are not sure that this part is the cause of the fault then we recommend that you do not go ahead with this purchase and instead seek further professional advice and diagnosis.


Benefits of using us:
  • Free round trip shipping
  • Fast & easy process
  • High quality components
  • 100% guaranteed or your money back
  • Save hundreds of dollars
  • Amazing customer service and support
  • No programming needed
  • Plug-n-play
  • Refurbished and tested to meet manufacturers specifications
  • IPC certified technicians (highest standard of quality craftsmanship)
  • Hassle-free warranty that is much better than the warranties you get for new replacements.
Warranty

Warranty

Our service is 100 percent guaranteed or your money back.

For a full 24 months, our no-hassle warranty covers the repair. We will fix the item again if the repair fails within 24 months. If the component is not repairable, we will, at our discretion, either replace the part entirely or refund the cost of the repair.

We stand by our services – If the part is going to fail, itll fail within the first 3 months. Thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

How It Works

How it works

Our services are fast and easy. Reducing downtime is extremely important to us. Our standard repair is usually under 1 week. Meanwhile, offering a high-quality repair service with a focus on quick, long-lasting repairs at competitive prices.


We take pride in our work and not only fully inspecting/repairing your faulty part, but will take it a step further and will replace failure prone components or parts that may be failing in the future. Each control board is fully tested to make sure it passes a full functional test. Our service is 100 percent guaranteed or your money back.


  1. Carefully remove your part.
  2. Securely pack your part, using the correct box so that your part cannot be damaged in transit. Take special care when packing.
  3. Add item to shopping cart and check out. We will provide you with shipping label to send the part to us. You will not need to pay anything until your part is full repaired.
  4. Inside the package include: Your Name, Return Address, Phone Number.


  5. International Shipping Available
    We ship to USA and Canada
Part Numbers

22BB033N204

Error Codes
CodeDescriptionRecommended Action
F100Parameter Checksum (Non-Resetable) The checksum read from the board does not match the checksum calculated.Set P041 [Reset To Defalts] to option 1 “Reset Defaults”
F12HW OverCurrent (Non-Resetable) The drive output current has exceeded the hardware current limit.Check programming. Check for excess load, improper A084 [Boost Select] setting, DC brake volts set too high or other causes of excess current.
F122I/O Board Fail (Non-Resetable) Failure has been detected in the drive control and I/O section.1. Cycle power. 2. Replace drive if fault cannot be cleared.
F13Ground Fault (Non-Resetable) A current path to earth ground has been detected at one or more of the drive output terminals.Check the motor and external wiring to the drive output terminals for a grounded condition.
F2Auxiliary Input (Auto-Reset/Run) Auxiliary input interlock is open.1. Check remote wiring. 2. Verify communications programming for intentional fault.
F29Analog Input Loss (Auto-Reset/Run) An analog input is configured to fault on signal loss. A signal loss has occurred. Configure with A122 [Analog In Loss].1. Check parameters. 2. Check for broken/loose connections at inputs.
F3Power Loss (Non-Resetable) Excessive DC Bus voltage ripple.1. Monitor the incoming line for phase loss or line imbalance. 2. Check input line fuse
F33Auto Rstrt Tries (Non-Resetable) Drive unsuccessfully attempted to reset a fault and resume running for the programmed number of A092 [Auto Rstrt Tries].Correct the cause of the fault and manually clear.
F38Phase U to Gnd (Non-Resetable) A phase to ground fault has been detected between the drive and motor in this phase.1. Check the wiring between the drive and motor. 2. Check motor for grounded phase. 3. Replace drive if fault cannot be cleared.
F39Phase V to Gnd (Non-Resetable) A phase to ground fault has been detected between the drive and motor in this phase.1. Check the wiring between the drive and motor. 2. Check motor for grounded phase. 3. Replace drive if fault cannot be cleared.
F4UnderVoltage (Auto-Reset/Run) DC bus voltage fell below the minimum value.Monitor the incoming AC line for low voltage or line power interruption.
F40Phase W to Gnd (Non-Resetable) A phase to ground fault has been detected between the drive and motor in this phase.1. Check the wiring between the drive and motor. 2. Check motor for grounded phase. 3. Replace drive if fault cannot be cleared.
F41Phase UV Short (Non-Resetable) Excessive current has been detected between these two output terminals.1. Check the motor and drive output terminal wiring for a shorted condition. 2. Replace drive if fault cannot be cleared.
F42Phase UW Short (Non-Resetable) Excessive current has been detected between these two output terminals.1. Check the motor and drive output terminal wiring for a shorted condition. 2. Replace drive if fault cannot be cleared.
F43Phase VW Short (Non-Resetable) Excessive current has been detected between these two output terminals.1. Check the motor and drive output terminal wiring for a shorted condition. 2. Replace drive if fault cannot be cleared.
F481. Clear the fault or cycle power to the drive. 2. Program the drive parameters as needed.
F5OverVoltage (Auto-Reset/Run) DC bus voltage exceeded maximum value.Monitor the AC line for high line voltage or transient conditions. Bus overvoltage can also be caused by motor regeneration. Extend the decel time or install dynamic brake option.
F6Motor Stalled (Auto-Reset/Run) Drive is unable to accelerate motor.Increase P039 - A067 [Accel Time x] or reduce load so drive output current does not exceed the current set by parameter A089 [Current Limit 1].
F63SW OverCurrent (Auto-Reset/Run) Programmed A098 [SW Current Trip] has been exceeded.Check load requirements and A098 [SW Current Trip] setting.
F64Drive Overload (Non-Resetable) Drive rating of 150% for 1 minute or 200% for 3 seconds has been exceeded.Reduce load or extend Accel Time.
F7Motor Overload (Auto-Reset/Run) Internal electronic overload trip.1. An excessive motor load exists. Reduce load so drive output current does not exceed the current set by parameter P033 [Motor OL Current]. 2. Verify A084 [Boost Select] setting
F70Power Unit (Non-Resetable) Failure has been detected in the drive power section.1. Cycle power. 2. Replace drive if fault cannot be cleared.
F711. Cycle power. 2. Check communications cabling. 3. Check network adapter setting. 4. Check external network status.
F8Heatsink OvrTmp (Auto-Reset/Run) Heatsink temperature exceeds a predefined value.1. Check for blocked or dirty heat sink fins. Verify that ambient temperature has not exceeded 40°C (104°F) for IP30, NEMA UL Type 1 installations or 50°C (122°F) for IP20/Open type installations. 2. Check fan.
F80Restart procedure.
F81Comm Loss (Non-Resetable) RS485 (DSI) port stopped communicating.1. If adapter was not intentionally disconnected, check wiring to the port. Replace wiring, port expander, adapters or complete drive as required. 2. Check connection. 3. An adapter was intentionally disconnected. 4. Turn off using A105 [Comm Loss Action].
Models

This control board may be found in models similar to the following:

22B-B033N204

 
Related products
VFD022M23B Delta Group Electronics AC VFD Variable Frequency Drive Repair
VFD022M23B Delta Group Electronics AC VFD Variable Frequency Drive Repair
$446.76
View Details
1336-B003-EOD-L1 Allen Bradley AC VFD Variable Frequency Drive Repair
1336-B003-EOD-L1 Allen Bradley AC VFD Variable Frequency Drive Repair
$556.92
View Details
20AD2P1A0AYNANC0 Allen Bradley AC VFD Variable Frequency Drive Repair
20AD2P1A0AYNANC0 Allen Bradley AC VFD Variable Frequency Drive Repair
$228.89
View Details
CFW-0900013T3848EON4Z Weg AC VFD Variable Frequency Drive Repair
CFW-0900013T3848EON4Z Weg AC VFD Variable Frequency Drive Repair
$122.50
View Details
×
22B-B033N204 Allen Bradley AC VFD Variable Frequency Drive Repair
1 image
  • 22B-B033N204 Allen Bradley AC VFD Variable Frequency Drive Repair image
1 guide
×
Contact Us