SKU: 28599

22A-A1P4N103 Allen Bradley AC VFD Variable Frequency Drive Repair

Industrial VFD Repair Service – Save Big and Keep Your Settings. Our services are fast and easy. Send us your failed VFD Variable Frequency Drive. We will quickly repair your faulty VFD. We provide a quick turnaround time and a high repair success rate at a low repair cost.
UpFix is NOT an authorized distributor for Allen Bradley.

Experience the most cost-effective and efficient solution for your industrial VFD issues with UpFix expert repair service. By choosing to repair your original VFD, you not only save significantly compared to the cost of buying a new unit, but you also retain all the custom programming and configurations specific to your operational needs.
  • Estimated Repair Time is 2-4 business days.
  • 2 Year Warranty
  • Real-Time Repair Tracking
  • Our service is 100% guaranteed or your money back. Order today and save!
  • International Shipping Available
  • Free shipping available at online checkout!
$170.75
$170.75
Service Price:
Options Price:
Total:
Description

Description

This is a repair service for 22A-A1P4N103 Allen Bradley AC VFD Variable Frequency Drive Repair.
UpFix is NOT an authorized distributor for Allen Bradley.

This repair is also for the following similar VFD model numbers:
22AA1P4N103.

Wide Range of Supported VFDs

Our repair services cover various makes and models, providing a dependable solution for virtually any type of VFD you might be using in your operations.

Why Repairing Your VFD with UpFix is the Better Choice:

  1. Cost Efficiency: Save up to 80%. Repairing a VFD is significantly more cost-effective than replacing it. Our services can save your business substantial expenditure, preserving capital for other strategic investments.
  2. Minimized Downtime: A malfunctioning VFD can halt production lines and disrupt operations. Our efficient repair process gets your systems back up and running quickly, reducing downtime and lost productivity.
  3. Eco-Friendly: Repairing your appliance with UpFix is a step towards sustainability. By refurbishing your existing control board, you help reduce electronic waste and conserve natural resources, supporting environmental conservation efforts.

Our Expert VFD Repair Process

When you send your VFD to UpFix, it undergoes a thorough diagnostic process to identify both evident and potential issues. We repair and replace defective components, and also proactively upgrade components that are known to fail over time. This comprehensive approach ensures extended reliability and performance of your VFD.


How It Works



Once we receive your part, our trained and IPC certified technicians will run tests to identify the source of the problem. We will rebuild your part, replacing not only the failed components, but all components that are usually known to fail or go bad in this part. We want to make your experience as effortless as possible. All you have to do is send your part to us. Then after receiving the part back from us, just reinstall it and you’re back in business!

What You Can Expect from UpFix

  • Send your faulty VFD to our repair center.
  • Our expert technicians will repair, test, and calibrate your VFD to ensure it meets all operational standards.
  • Receive your VFD back and reintegrate it into your system with confidence in its functionality.
  • No Reconfiguration Needed

Added Benefits of Choosing UpFix

  • Estimated Repair Time is 2-4 business days.

  • International shipping options to the USA and Canada.
  • Comprehensive testing post-repair to guarantee performance.
  • A 24-month warranty and lifetime phone support, underlining our commitment to quality and customer satisfaction.
  • We uphold the highest standards of integrity and community support in all our business practices.

Additional Benefits of Choosing UpFix

  • Estimated Repair Time is 2-4 business days.

  • Fast turnaround times to help keep your operations smooth.
  • Service available across the USA and Canada with reliable shipping options.
  • Each VFD is thoroughly tested post-repair to ensure it passes all performance and safety tests.
  • 24-month warranty and lifetime technical support guarantee your satisfaction and peace of mind.
  • We are committed to the highest standards of service and customer satisfaction.

We take pride in our work and will take it a step further and fully inspect your control board and will replace failure prone components or parts that may be failing in the future. Each control board is fully tested to make sure it passes a full functional test.

Our service is 100 percent guaranteed or your money back. We stand by our services – If the part is going to fail, itll fail within the first 24 months. Thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

Our goal is to save you hundreds of dollars, while continuing to provide an eco-friendly solution that reduces pollution. We drive our business towards consistent and profitable growth, with integrity and a commitment to the people and communities where we live and work. Our service is 100% guaranteed or your money back.



This repair service will fix these issues:

  • Auto Tune Failure
  • Checksum Fault
  • Does Not Enable
  • Does Not Power
  • Fails Under Load
  • Fans Not Turning On
  • Ground Fault
  • Heatsink Fault
  • I/O Terminal Not Working
  • Input Phase Fault
  • Keypad Issue
  • Keys Dont Press
  • No Output
  • Output Phase Fault
  • Output Runs Erratically
  • Overcurrent Fault
  • Overvoltage Fault
  • Power Loss
  • Undervoltage Fault
  • Unit Had Blown Up
  • Unit Smoked

Cost-Effective


Repairing your existing VFD can be substantially more affordable than purchasing a new one. Enjoy significant savings while maintaining optimal functionality.

No Reconfiguration Needed


One of the biggest advantages of repairing your original VFD is the elimination of reprogramming. Your VFD will be returned to you with all its original settings intact, ensuring a seamless reintroduction into your system without the need for costly and time-consuming reconfiguration.

Quick Turnaround


We understand the importance of minimizing downtime. Our skilled technicians ensure a quick and efficient repair process, getting your operations back up and running in no time.

Quality Assurance


We use only the highest quality parts and the latest techniques in our repair processes, ensuring your VFD returns to you in top-notch condition, often better than its pre-fault state.

Extended Life for Your Equipment


Repairing and maintaining your existing VFD can significantly extend its life, making it a sustainable choice for your business and the environment.

Expert Support


Our team of experienced technicians is well-versed in a wide range of VFD brands and models, providing you with knowledgeable support and advice every step of the way.

Our Commitment


At UpFix, we are committed to providing you with a reliable, high-quality repair service that keeps your operations smooth and efficient. Trust us to restore your VFD to its optimal performance, ensuring your business runs uninterrupted.
Will this service fix my problems?

A full diagnostic check should first be performed to eliminate all other possible causes for your symptoms, even if the symptoms match those specified on the common fault description.

If you send a unit in good working condition due to misdiagnosis, and our testing determines that there are no issues or faults with the unit, or if the part is beyond repair, then you will only be responsible for the shipping costs and a bench test fee of $39.99 may be applied.

IMPORTANT! If you are not sure that this part is the cause of the fault then we recommend that you do not go ahead with this purchase and instead seek further professional advice and diagnosis.


Benefits of using us:
  • Free return trip shipping
  • Save hundreds of dollars
  • Fast & easy process
  • High quality components
  • 100% guaranteed or your money back
  • Amazing customer service and support
  • No programming needed
  • Plug-n-play
  • Refurbished and tested to meet manufacturers specifications
  • IPC certified technicians (highest standard of quality craftsmanship)
  • Hassle-free warranty that is much better than the warranties you get for new replacements.
Warranty

Warranty

Our service is 100 percent guaranteed or your money back.

For a full 24 months, our no-hassle warranty covers the repair. We will fix the item again if the repair fails within 24 months. If the component is not repairable, we will, at our discretion, either replace the part entirely or refund the cost of the repair.

We stand by our services – If the part is going to fail, itll fail within the first 3 months. Thats why we got you covered with a 24-month warranty and lifetime phone support when you need us

How It Works

How It Works

Our services are fast and easy. Reducing downtime is extremely important to us. Our standard repair is usually under 1 week. Meanwhile, offering a high-quality repair service with a focus on quick, long-lasting repairs at competitive prices.


We take pride in our work and not only fully inspecting/repairing your faulty part, but will take it a step further and will replace failure prone components or parts that may be failing in the future. Each control board is fully tested to make sure it passes a full functional test. Our service is 100 percent guaranteed or your money back.


  1. Carefully remove your part.
  2. Securely pack your part, using the correct box so that your part cannot be damaged in transit. Take special care when packing.
  3. Add item to shopping cart and check out. We will provide you with shipping label to send the part to us. You will not need to pay anything until your part is full repaired.
  4. Inside the package include: Your Name, Return Address, Phone Number.


  5. International Shipping Available
    We ship to USA and Canada
Part Numbers

22AA1P4N103

Error Codes
CodeDescriptionRecommended Action
F100Parameter Checksum (Non-Resetable) The checksum read from the board does not match the checksum calculated.Set P041 [Reset To Defalts] to option 1 “Reset Defaults”.
F12HW OverCurrent (Non-Resetable) The drive output current has exceeded the hardware current limit.Check programming. Check for excess load, improper A084 [Boost Select] setting, DC brake volts set too high or other causes of excess current.
F122I/O Board Fail (Non-Resetable) Failure has been detected in the drive control and I/O section.1. Cycle power. 2. Replace drive if fault cannot be cleared.
F13Ground Fault (Non-Resetable) A current path to earth ground has been detected at one or more of the drive output terminals.Check the motor and external wiring to the drive output terminals for a grounded condition.
F2Auxiliary Input (Auto-Reset/Run) Auxiliary input interlock is open.1. Check remote wiring. 2. Verify communications programming for intentional fault
F3Power Loss (Non-Resetable) DC bus voltage remained below 85% of nominal.1. Monitor the incoming AC line for low voltage or line power interruption. 2. Check input fuses.
F33Auto Rstrt Tries (Non-Resetable) Drive unsuccessfully attempted to reset a fault and resume running for the programmed number of A092 [Auto Rstrt Tries].Correct the cause of the fault and manually clear.
F38Phase U to Gnd (Non-Resetable) A phase to ground fault has been detected between the drive and motor in this phase.1. Check the wiring between the drive and motor. 2. Check motor for grounded phase. 3. Replace drive if fault cannot be cleared.
F39Phase V to Gnd (Non-Resetable) A phase to ground fault has been detected between the drive and motor in this phase.1. Check the wiring between the drive and motor. 2. Check motor for grounded phase. 3. Replace drive if fault cannot be cleared.
F4UnderVoltage (Auto-Reset/Run) DC bus voltage fell below the minimum value.Monitor the incoming AC line for low voltage or line power interruption.
F40Phase W to Gnd (Non-Resetable) A phase to ground fault has been detected between the drive and motor in this phase.1. Check the wiring between the drive and motor. 2. Check motor for grounded phase. 3. Replace drive if fault cannot be cleared.
F41Phase UV Short (Non-Resetable) Excessive current has been detected between these two output terminals.1. Check the motor and drive output terminal wiring for a shorted condition. 2. Replace drive if fault cannot be cleared.
F42Phase UW Short (Non-Resetable) Excessive current has been detected between these two output terminals.1. Check the motor and drive output terminal wiring for a shorted condition. 2. Replace drive if fault cannot be cleared.
F43Phase VW Short (Non-Resetable) Excessive current has been detected between these two output terminals.1. Check the motor and drive output terminal wiring for a shorted condition. 2. Replace drive if fault cannot be cleared.
F48F481. Clear the fault or cycle power to the drive. 2. Program the drive parameters as needed.
F5OverVoltage (Auto-Reset/Run) DC bus voltage exceeded maximum value.Monitor the AC line for high line voltage or transient conditions. Bus overvoltage can also be caused by motor regeneration. Extend the decel time or install dynamic brake option.
F6Motor Stalled (Auto-Reset/Run) Drive is unable to accelerate motor.Increase P039 - A067 [Accel Time x] or reduce load so drive output current does not exceed the current set by parameter A089 [Current Limit].
F63SW OverCurrent (Auto-Reset/Run) Programmed A098 [SW Current Trip] has been exceeded.Check load requirements and A098 [SW Current Trip] setting.
F64Drive Overload (Non-Resetable) Drive rating of 150% for 1 minute or 200% for 3 seconds has been exceeded.Reduce load or extend Accel Time.
F7Motor Overload (Auto-Reset/Run) Internal electronic overload trip. 1. An excessive motor load exists. Reduce load so drive output current does not exceed the current set by parameter P033 [Motor OL Current]. 2. Verify A084 [Boost Select] setting
F70Power Unit (Non-Resetable) Failure has been detected in the drive power section1. Cycle power. 2. Replace drive if fault cannot be cleared.
F711. Cycle power. 2. Check communications cabling. 3. Check network adapter setting. 4. Check external network status.
F8Heatsink OvrTmp (Auto-Reset/Run) Heatsink temperature exceeds a predefined value.1. Check for blocked or dirty heat sink fins. Verify that ambient temperature has not exceeded 40°C (104°F) for IP 30/NEMA 1/UL Type 1 installations or 50°C (122°F) for IP20/Open type installations. 2. Check fan.
F81Comm Loss (Non-Resetable) RS485 (DSI) port stopped communicating.1. If adapter was not intentionally disconnected, check wiring to the port. Replace wiring, port expander, adapters or complete drive as required. 2. Check connection. 3. An adapter was intentionally disconnected. 4. Turn off using A105 [Comm Loss Action].
Models

This control board may be found in models similar to the following:

22A-A1P4N103

Related products
6KG1123001X4B1 GE General Electric AC VFD Variable Frequency Drive Repair
6KG1123001X4B1 GE General Electric AC VFD Variable Frequency Drive Repair
$387.20
View Details
CFW300 B 01P8 T4DB20 Weg AC VFD Variable Frequency Drive Repair
CFW300 B 01P8 T4DB20 Weg AC VFD Variable Frequency Drive Repair
$77.64
View Details
6KAF343002E$A1 GE General Electric AC VFD Variable Frequency Drive Repair
6KAF343002E$A1 GE General Electric AC VFD Variable Frequency Drive Repair
$522.90
View Details
CFW300 B 06P5 T4 DB20 Weg AC VFD Variable Frequency Drive Repair
CFW300 B 06P5 T4 DB20 Weg AC VFD Variable Frequency Drive Repair
$129.23
View Details
×
22A-A1P4N103 Allen Bradley AC VFD Variable Frequency Drive Repair
1 image
  • 22A-A1P4N103 Allen Bradley AC VFD Variable Frequency Drive Repair image
2 videos
  • 22A-A1P4N103 Allen Bradley AC VFD Variable Frequency Drive Repair video
  • 22A-A1P4N103 Allen Bradley AC VFD Variable Frequency Drive Repair video
1 guide
×